Search Frequent Questions
Filter By:
- Southeast Minnesota Groundwater Total results: 11
- Air Emissions Inventories Total results: 34
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 17
- Coronavirus (COVID-19) Total results: 33
- East Palestine, Ohio Train Derailment Total results: 148
- Emergency Planning and Community Right-to-Know Total results: 301
- Fuel Program Total results: 693
- Great Lakes Funding Total results: 49
- Lead Total results: 401
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
-
Oil Regulations
Total results: 96
-
40 CFR Part 112 Spill Prevention, Control, and Countermeasure Rule
Total results: 65
- 112.1 Applicability Total results: 18
- 112.2 Definitions Total results: 12
- 112.3 Requirement to Prepare an SPCC Plan Total results: 3
- 112.6 Qualified Facilities Total results: 4
- 112.7 General Requirements Total results: 17
- 112.8 Specific Onshore Requirements (Excluding Production) Total results: 3
- Miscellaneous SPCC Total results: 8
- 40 CFR Part 110 Discharge of Oil Regulation Total results: 9
- 40 CFR Part 112.20 Facility Response Plans Total results: 19
- 40 CFR Part 300 Subpart J Total results: 1
- Miscellaneous Oil Total results: 2
-
40 CFR Part 112 Spill Prevention, Control, and Countermeasure Rule
Total results: 65
- Permitting Under the Clean Air Act Total results: 13
- Radiation Total results: 1
- Risk Management Program (RMP) Total results: 285
Active filters:
Remove all filtersDisplaying 46 - 60 of 76 results
-
What are the amended requirements for oil-filled operational equipment?
Instead of providing secondary containment for qualified oil-filled operational equipment, an owner or operator may prepare an oil spill contingency plan and a written commitment of manpower, equipment, and materials to quickly control and remove discharged oil. He/she must also have an inspection or monitoring program for the equipment to…
- Last published:
-
PE certification and applying PE's seal
Except as provided in 40 CFR §112.6 for qualified facilities, a Professional Engineer (PE) must certify a facility’s SPCC Plan. In order to certify an SPCC plan, must a PE apply his seal to the plan, or is the PE’s signature on a certification statement sufficient for SPCC purposes? For…
- Last published:
-
What types of oil does the SPCC Rule address?
The term oil means oil of any kind or in any form, including, but not limited to: petroleum; fuel oil; sludge; oil refuse; oil mixed with wastes other than dredged spoil; fats, oils or greases of animal, fish, or marine mammal origin; vegetable oils, including oil from seeds, nuts, fruits…
- Last published:
-
PE certifying a technical amendment
Except as provided in 40 CFR §112.6 for qualified facilities, a Professional Engineer (PE) must certify all technical amendments to an existing SPCC Plan (§112.5(c)). When certifying a technical change to an existing SPCC Plan, does the PE have to inspect and certify the entire Plan or only the amended…
- Last published:
-
Leasing out empty oil storage containers.
A facility leases out empty stationary tanks to other facilities that use the tanks to store oil (e.g., gasoline). The stationary tanks are empty while at the initial facility and eventually leased to other customers to be reused for oil storage. Is the facility that leases out the empty tanks…
- Last published:
-
Inspection or monitoring program requirements when using alternative secondary containment for oil-filled operational equipment
Instead of providing secondary containment for qualified oil-filled operational equipment, an owner or operator may prepare an oil spill contingency plan and a written commitment of manpower, equipment, and materials to quickly control and remove discharged oil. He/she must also have an inspection or monitoring program for the equipment to…
- Last published:
-
When is a mobile refueler subject to SPCC requirements?
According to a 1971 Memorandum of Understanding between the Department of Transportation (DOT) and the Environmental Protection Agency, EPA regulates non-transportation-related facilities and DOT regulates transportation-related facilities: • Mobile refuelers that operate solely within the confines of a non-transportation-related facility subject to the SPCC rule must comply with the general…
- Last published:
-
How are people potentially exposed to nitrate?
For many situations, the potential for children’s exposure from drinking water is medium to low. The potential can be higher when private wells become contaminated with nitrates from feed lot and agricultural runoff, and contaminated groundwater. Some geographic areas are at higher risk of drinking water contamination of private wells…
- Last published:
-
What are the possible health effects of nitrate exposure?
Short-term: Excessive levels of nitrate in drinking water have caused serious illness and sometimes death. The serious illness in infants is due to the conversion of nitrate to nitrite by the body, which can interfere with the oxygen-carrying capacity of the child’s blood leading to blue baby syndrome (methemoglobinemia). This…
- Last published:
-
What is nitrate?
Nitrate (NO3) is a compound of nitrogen and oxygen naturally found in air, soil, water, and some food. Plants and animals require nitrates for their survival and growth, and the human body also produces this compound. In industry, nitrate is used as fertilizers for crops and lawns. Additionally, nitrates are…
- Last published:
-
I use a carbon filter. Will this help?
Activated carbon filters, such as those in a “Brita” water pitcher, DO NOT remove nitrates.
- Last published:
-
Can a containment wall be constructed out of concrete blocks?
Yes. SPCC regulations do not mandate design specifications, rather, they are performance based. Therefore, a containment wall may be of any construction type, material, or design, assuming it meets the performance standards and requirements of Part 112. Regional offices can help determine whether individual containment equipment meets the performance standards…
- Last published:
-
Qualifying criterion for qualified oil-filled operational equipment
What is the qualifying criterion for the option for qualified oil-filled operational equipment? Equipment is eligible if the facility did not discharge from any oil-filled operational equipment (1) more than 1,000 U.S. gallons of oil in a single discharge to navigable waters, or (2) discharge more than 42 U.S. gallons…
- Last published:
-
For SPCC training purposes, who is considered oil-handling personnel?
Pursuant to 112.7(f)(1), the owner or operator of a facility subject to the SPCC regulations must train oil-handling personnel in the operation and maintenance of equipment, discharge procedure protocols, applicable pollution control laws, rules and regulations, general facility operations and the contents of the facility SPCC Plan. For the purposes…
- Last published:
-
Tier I qualified facility template use under Part 112
In the 2008 Amendments to the SPCC Rule, EPA provided a template for the owner or operator of a Tier I qualified facility to create an SPCC Plan. Does EPA require a Tier I qualified facility to use the template in 40 CFR Part 112, Appendix G? Does EPA allow…