Search Frequent Questions
Filter By:
-
Fuel Program
Total results: 693
- Diesel Sulfur Program Total results: 7
- E15 comments Total results: 1
- Fuels and Fuel Additives (FFARs) Total results: 2
- Gasoline Sulfur Program Total results: 17
- Other Total results: 6
- Reformulated Gasoline and Anti-Dumping Total results: 431
- Registration Total results: 9
- Registration and Reporting under 40 CFR 79 Total results: 19
- Renewable Fuel Standard (RFS1) Total results: 67
- Renewable Fuel Standard (RFS2) Total results: 111
- Reporting Total results: 22
-
Lead
Total results: 398
- Applying for Certification or Accreditation Total results: 22
- EPA/HUD Real Estate Notification & Disclosure Rule Total results: 24
- General Information About Lead Total results: 9
- Lead-Based Paint Program Fees Total results: 9
- Lead Abatement, Risk Assessment and Inspection Total results: 49
- Lead at Superfund Sites Total results: 3
- Lead in Drinking Water Total results: 25
- Lead in Products Total results: 1
- Lead Renovation, Repair and Painting Total results: 237
- Testing for Lead Total results: 19
- Air Emissions Inventories Total results: 34
- Asbestos Total results: 141
- Butte Area/Silver Bow Creek Total results: 17
- Coronavirus (COVID-19) Total results: 33
- East Palestine, Ohio Train Derailment Total results: 148
- Emergency Planning and Community Right-to-Know Total results: 301
- Great Lakes Funding Total results: 92
- MOVES Total results: 57
- Norwood Landfill Site Total results: 30
- Oil Regulations Total results: 96
- Permitting Under the Clean Air Act Total results: 19
- Radiation Total results: 1
- Risk Management Program (RMP) Total results: 285
- Southeast Minnesota Groundwater Total results: 11
Displaying 16 - 30 of 1091 results
-
In the case of an RBOB refiner conducting oversight over the RFG produced at a downstream oxygenate blending operation, what standards does EPA intend that the refiner should check through sampling and testing?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Under § 80.69(a) an RBOB refiner is required to calculate the non-oxygen parameter values for the RFG produced from the RBOB using either the oxygen blending assumptions under § 80.69(a)(8), or the actual oxygen blending levels if the…
- Last published:
-
Today, and with the Phase I complex model, there is effectively a 1 RVP difference between the Region 1 and 2 standards. In Phase II, this difference basically drops to 0 RVP. Was this intended, and why?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . The Phase 2 Volatility Standards (55 FR 23658 (June 11, 1990)) provided the basis for the different RVP standards, depending on VOC Control Region, for reformulated gasoline under the Simple Model. The standards for VOC emissions performance for…
- Last published:
-
In the case of a refiner or importer using the 100% independent analysis option, must the refiner or importer conduct any sampling or testing of RFG in addition to that performed by the independent lab?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . A refiner or importer using the 100% independent analysis option must use the test results from the designated independent lab as the basis for all RFG reports to EPA. The RFG regulations do not prohibit a refiner or…
- Last published:
-
Is EPA documentation necessary to settle inventory over/short accounts where the volume of gasoline involved is de minimis? If so, what are the parties documenting?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . PTD information is only required when there is a transfer of title or custody of any gasoline (with the exception of gasoline sold or dispensed at a retail outlet or wholesale purchaser-consumer for use in motor vehicles). As…
- Last published:
-
In the GC-MS test for aromatics, why must the calibration curves be forced through the origin? All mass spectrometers will show some noise at a zero concentration level.
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Calibration curves are not required to be forced through the origins. The reference in the regulation is a suggested method.(7/1/94) This question and answer was posted at Consolidated List of Reformulated Gasoline and Anti-Dumping Questions and Answers: July…
- Last published:
-
In theory, each step of the RFG testing chain could yield varying (assuming increased) results due to reproducibility -- what is EPA's position on this?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . It is up to the regulated parties to determine margins of safety. EPA does not get involved in this determination.(8/29/94) This question and answer was posted at Consolidated List of Reformulated Gasoline and Anti-Dumping Questions and Answers: July…
- Last published:
-
If one company acquires foreign product in transit, then sells it to a second company while still in transit, who is the importer?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . The importer is the party identified above, the party primarily liable for payment of duties for Customs purposes when the gasoline enters the United States.(7/1/94) This question and answer was posted at Consolidated List of Reformulated Gasoline and…
- Last published:
-
Does EPA make any distinction in terms of timeliness between PTD's which memorialize a transfer of title as opposed to those which memorialize a transfer of custody? For example, exchange statements detailing liftings by an exchange partner ordinarily are
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Section 80.77 does not distinguish between transfers of custody and transfers of title. Nevertheless, EPA believes the two situations may be different in terms of the timing necessary for PTD information. In the case of transfers of custody…
- Last published:
-
Explain the volume determination requirement for independent labs.
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Section 80.65(f)(3)(i)(B) requires the independent lab to determine the volume of each RFG batch that is sampled. EPA expects the independent lab will determine the volume of a RFG batch in the same manner gasoline volumes currently are…
- Last published:
-
There are situations where ethanol will be present in very small quantities in RFG produced using other oxygenates. For example, ETBE often contains very small amounts of ethanol, less than 2%. As a result, will EPA apply a de minimis exception to the pro
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Section 80.78(a)(8) prohibits the mixing of VOC-controlled RFG produced using ethanol with VOC-controlled RFG produced using any other oxygenate during the period January 1 through September 15. EPA will not consider this prohibition violated, however, in the case…
- Last published:
-
Confirm that an RFG property measured from a sample collected during an EPA inspection is in technical violation if that property exceeds an applicable standard, but that no enforcement action will be brought by EPA unless the property exceeded the standa
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . As stated in the preamble to the RFG final rule, at 59 FR 7764 (February 16, 1994), EPA will not initiate an enforcement action on the basis of a test result from a gasoline sample collected at a…
- Last published:
-
During a transition period, refiners will produce VOC-controlled RFG that is blended with non VOC-controlled RFG downstream of the refinery in order to blend down RVP prior to the beginning of the VOC season. How will the resultant mixture be classified a
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . The resulting gasoline should be listed as non VOC-controlled RFG on the PTD's, unless the resulting blend meets the requirements to be designated as VOC-controlled gasoline.(7/1/94) This question and answer was posted at Consolidated List of Reformulated Gasoline…
- Last published:
-
What are the requirements for reporting to EPA in the case of an independent lab that conducts sampling and testing that is unrelated to the independent sampling and testing requirements that apply for refiners or importers, such as quality assurance samp
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . There is no requirement that the results of downstream quality assurance sampling and testing must be reported to EPA. This is true both in the case of quality assurance sampling and testing by downstream parties such as pipelines…
- Last published:
-
EPA has stated that a Product Transfer Document must be provided to the transferee in an exchange transaction. Is this true when this exchange is instantaneous and the transferee has no ability to alter the product?
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Yes. When any person transfers title or custody of any gasoline (with the exception of gasoline sold or dispensed at a retail outlet or wholesale purchaser-consumer for use in motor vehicles), the transferor must provide to the transferee…
- Last published:
-
Please describe the survey areas which are currently applicable.
See More Frequent Questions about Fuels Registration, Reporting, and Compliance Help . Attached to this document as Attachment II is a list of the presently applicable survey areas including opt-in areas. This list is current as of June, 1994. (The Agency has promulgated a "corrections notice" which defines these areas.)(7/1/94)…
- Last published: